The Total Steam System is comprised of:
  1. Boilers
  2. Deaerators/Boiler Feed System
  3. Blowdown Separator/Valves
  4. Blowdown Heat Recovery
  5. Chemical Feed System
  6. Water Softeners
  7. Economizer
  8. Stacks and Breeching
  9. Chimney Automation/Draft Controls
  10. Combustion Air Systems
  11. Semi Instantaneous Water Heater
  12. Multi System Boiler Controls
  13. Oxygen Trim Systems
  14. Sample Cooler
  15. Dealkalizer
  16. Water Filter/Reverse Osmosis System
  17. The Boiler Book

 

1. BOILER TYPES AVAILABLE

FIRETUBE BOILERS (Horizontal Scotch Marine)
Designs: 15 - 350 PSIG Steam and Hot Water

  • Four Pass Dry Back 15-800 HP, Premium Integral Front Head Burner
  • Four Pass Wetback 100 - 1800 Hp
  • "Intercooled Rear Head" Four Pass 100 - 800 HP
  • Three or Four Pass Dry Back 60-350 HP

    Features: High turndown / low NOx burners; custom control packages; complete boiler room packages for single source responsibility
    Representing: Cleaver-Brooks

    Request Information    Back to top


  •  

    INDUSTRIAL WATERTUBE BOILERS
    Designs: to 1,500 psig Steam & High Temperature Water
  • "D" Style, 10,000 - 150,000 lbs/hr.
  • "A" Style, 30,000 - 250,000 lbs/hr
  • "O" Style, 10,000 - 80,000 lbs/hr
    Features: Saturated or superheated steam; Tangent Tube or Welded Membrane Walls; high turndown/low NOx burners; custom control packages; complete boiler room packages for single source responsibility
    Representing: Cleaver-Brooks and Nebraska Boiler

  • Request Information    Back to top

    COMMERCIAL WATERTUBE BOILERS
    Designs: 15 -150 psig Steam and Hot Water
    Sizes: 1,500 - 12,600 MBH (36 - 300 HP)
    Features: Tangent-wall Flextube design, custom control packages, Low NOx
    Highly resistant to thermal shock
    Representing: Cleaver-Brooks


    Request Information    Back to top

    Clearfire H - steam
    Sizes: 15-40 HP
    Features:
    An extremely compact firetube, meets low and high pressure steam and hydronic heating requirements. Ideal for small process and/or heating loads burning natural gas or propane. Multi-purpose design; Exceptional efficiencies (85%) and high turndown (4:1). Key: Revolutionary Alufer tubes (ten times the heat transfer), and the high radiant pre-mix burner with VFD delivering <70 dBA noise levels and <30 ppm NOx emissions as STANDARD.
    Representing: Cleaver-Brooks

    Request Information    Back to top

    VERTICAL BOILERS
    Designs: 15 - 300 PSIG Steam and Hot Water

  • Tubeless Design 5 - 60 HP
  • Multi-Pass Design 40 - 130 HP
    Features: Skid mounted Boiler systems prepiped and wired, Low NOx burners
    Representing: Fulton
  • Request Information    Back to top


    ELECTRIC BOILERS
    Designs: 15 - 300 psig Steam and Hot Water
    Sizes: 12 to 3375 KW (42 lbs/hr to 10,080 lbs/hr steam)
    Custom design electrode boilers
    Features: Multi-stage; SCR control option; Stainless steel elements
    Representing: Fulton and Cleaver-Brooks

    Request Information    Back to top

    INCLINED WATERTUBE BOILERS
    Designs: 15 -150 PSIG Steam and Hot Water
    Sizes: 15 - 21,000 MBH (3.7 - 514 HP)
    Features: Straight Tube design; atmospheric or forced draft burners; Low NOx burners; highly resistant to thermal shock
    Representing: Ajax Boiler Company


    Request Information   Back to top

    PULSE COMBUSTION FIRETUBE BOILERS
    Designs: 15 -150 psig Steam
    Sizes: 500,000 - 750,000 BTU/Hr (13 - 17 HP)
    Features: Sealed Combustion, Small diameter venting, Side Wall Venting, High Efficiency, Low NoX
    Representing: Fulton


    Request Information   Back to top

    WASTE HEAT BOILERS
    Designs: Custom designed Watertube and Firetube heat recovery boilers
    Features: Saturated or superheated steam, Supplemental firing, economizers, ductwork, stacks, complete system warranty and full design & support services.
    Applications: Turbine Exhaust, Engine Exhaust, Thermal Oxidizers, Process Gas Cooling and other special applications.
    Representing: Energy Recover International (ERI)

    Request Information   Back to top

    2. FEEDWATER SYSTEMS

     

    DEAERATORS
    Purpose: Remove corrosive gases from boiler feed water to protect against boiler and steam line corrosion; substantially reduce chemical usage and boiler blowdown requirements. Typical DA packages operate at 5-15 psi and include ASME storage tank, boiler feed pump(s), suction piping, control package, electrical panel and structural steel stand.
    Applications: Fresh water makeup exceeds 25%; boiler operating pressure above15 psi; production depends on continuous operation.
    Designs: Spray Head, Packed Column and Tray Type
    Sizes: 3,500 - 280,000 lbs/hr. (Larger custom design sizes available)
    Representing: Cleaver-Brooks and BFS Industries

    Request Information    Back to top

    FEEDWATER SYSTEMS
    Purpose: Receive and store condensate return; provide fresh water makeup as required; Typical feedwater systems are vented to atmosphere and include non-ASME storage tank, boiler feed pump(s), suction piping, control package, electrical panel and stand. Steam injection preheat systems are often included to maintain minimum boiler water temperature.
    Features: Vertical or horizontal tank configuration; lined, galvanized or stainless steel tanks
    Representing: Cleaver-Brooks, Fulton and BFS Industries

    Request Information    Back to top

    SURGE TANKS
    Purpose: Supplement DA storage capacity; collect low-pressure condensate returns. Provide continuous makeup to deaerator reducing DA tank size; Typical surge tank systems are vented to atmosphere and include storage tank, transfer pump(s), suction piping, control package, electrical panel and stand.
    Sizes: 300 - 3000 gallon storage tanks
    Representing: Cleaver-Brooks and BFS Industries

    Request Information    Back to top

    3. BOTTOM BLOWDOWN SYSTEMS

    BLOWDOWN SEPARATOR
    Purpose: Provide safe and effective means to collect and cool boiler blowdown to required temperature for drain. Flash steam is vented to atmosphere and cooled water goes to drain.
    Features: ASME code Flash Tanks; Manual or automatic aftercooler options
    Representing: Cleaver-Brooks, Fulton and Ajax Boiler

    Request Information    Back to top

    BLOWDOWN VALVES
    ASME Blowdown valves, quick and slow opening
    Representing: Everlasting Valve

    Request Information    Back to top

    4. SURFACE BLOWDOWN SYSTEMS

    BLOWOFF HEAT RECOVERY
    Purpose: Recover waste heat from continuous boiler surface blowdown by preheating boiler feed water before it enters feedwater tank or DA. Units automatically control blowdown rate to maintain desired level of dissolved solids in boiler water and recover up to 90% of available heat normally lost to drain.
    Representing: Cleaver-Brooks

    Request Information    Back to top

    FLASH TANK HEAT RECOVERY
    Purpose: Similar to the Blowdown Heat Recovery system except for the addition of a ASME code flash tank to provide the added benefit of utilizing the flash steam from blowdown. Flash steam is piped to the deaerator or low pressure steam header.
    Representing: Cleaver-Brooks

    Request Information    Back to top

    5. CHEMICAL FEED SYSTEMS

    CHEMICAL FEED SYSTEMS
    Purpose: provides means of injecting necessary chemicals into the feedwater tank and/or boiler to control corrosive gases and prevent scale formation in the boiler. Systems include storage tank, pump(s), mixer, stand, and optional electrical panel. Sizes: 50 to 200 gallons.
    Representing: Cleaver-Brooks

    Request Information    Back to top

    6. WATER SOFTENERS

    WATER SOFTENER
    Purpose: Soften boiler feed water by exchanging hardness minerals (calcium and magnesium ions) with sodium ions forming a soluble non-scaling mineral that will not build up on hot surfaces. Softener systems include single or multiple resin tanks, brine system, salt storage, and automatic regeneration controls. Options include ASME tanks, special lining, skid mounting, and special controls. Representing: Cleaver-Brooks and Fulton

    Request Information    Back to top

    7. ECONOMIZER STACK HEAT RECOVERY

    ECONOMIZERS (AIR TO WATER)
    Recover waste heat from the boiler flue gas and transfer heat to desired heat sink (boiler feed water, domestic water, etc.)

  • Increases overall boiler efficiency
  • Vertical, horizontal and cylindrical arrangements.
  • Payback analysis available.

  • Representing:
    Cleaver-Brooks, Cain, ERI

    Request Information    Back to top

    8. FLUE VENTING SYSTEMS

    BOILER BREECHING AND STACK SYSTEMS
  • UL Listed Flue Venting systems for category I, II, III and IV appliances
  • Single and Double wall (air or fiber insulated)
  • Positive, neutral and negative pressures
  • Stainless Materials of construction: 304, 316, and AL29-4C.
  • Job Specific vent sizing and Cad drawings available.
    Representing: Selkirk-Metalbestos, Heat-Fab, and Cleaver-Brooks

  • Request Information    Back to top

    9. MECHANICAL DRAFT SYSTEM

    MECHANICAL DRAFT SYSTEM
    Purpose: Ensure boilers operate at maximum efficiency by providing constant draft at all firing rates. System senses draft and modulates fan speed as stack conditions or firing rate change to maintain desired draft setting. System corrects difficult venting arrangements, allows different category appliances to be connected to a common stack and often reduces vent size and stack height. Vent sizing is determined and guaranteed by the manufacturer.
    Representing: Exhausto


    Request Information    Back to top

    10. MECHANICAL COMBUSTION AIR SYSTEM

    MODULATING COMBUSTION AIR SYSTEM
    Purpose: Provide make-up combustion air to boiler room to match burner requirements. System senses room air pressure and modulates variable speed fan to match combustion air to burner firing rate by maintaining a constant room pressure. Replaces large combustion air louvers which often introduce excess cold air into the boiler room.
    Representing: Exhausto


    Request Information    Back to top

    11. POTABLE WATER HEATERS

    POTABLE WATER HEATERS
    Purpose: Provide potable hot water on demand with or without storage tank utilizing an existing steam source. Provides temperature control of +-4 degrees F. from setpoint with steam condensate cooled to 200 degrees or less.
  • Semi-instantaneous sizes to 300 gpm, single or double wall coil, vertical or horizontal configurations, packaged with valves and controls.
  • Packaged storage water heaters with tanks to 5000 gallons
  • Unfired clean steam generators, copper, cupro-nickle, or 316L coils
    Representing: Ace Boiler

  • Request Information    Back to top

    12. BOILER CONTROL SYSTEMS
    MULTI SYSTEM BOILER CONTROLS
  • Combustion control systems and instrumentation packages
  • "HAWK" integrated combustion and flame safeguard systems with sequencing and communication options
  • Multiple boiler lead-lag sequencing systems
  • mod-bus capabilities
    Representing: Cleaver-Brooks, Century Controls, Heat-Timer
  • Request Information    Back to top

    Combustion Control
    Purpose: improve air to fuel ratios by replaces typical single point positioning (jackshaft linkage and cam controls) with Parallel Positioning. Parallel positioning microprocessor-based technology maintains precise independent control of air and fuel throughout the burner's operating range. It offers a high degree of accuracy and dependability and will maintain optimum efficiencies.
    Applications: Single or dual fuel with or without FGR.
    Options: Oxygen trim, multiple boiler lead-lag control, communications
    Representing: Cleaver-Brooks

    Request Information    Back to top

    13. OXYGEN TRIM SYSTEMS

    OXYGEN TRIM SYSTEM
    Purpose:
    maintain optimum fuel-to-air ratios and maximize combustion efficiency by continually monitoring the stack o2 levels and automatically adjusting o2 levels.
    Features: Accurate fast response Zircconia In-Situ probe, microprocessor based analyzer with graphic trending, pneumatic control components and actuator.
    Representing: Cleaver-Brooks

    Request Information    Back to top

    14. SAMPLE COOLERS

    SAMPLE COOLERS
    Purpose: To cool boiler water or steam samples to temperatures acceptable for testing without interfering with boiler plant operation.
  • Water samples to 850 degrees
  • Steam sample to 5000 psi
    Representing: Cleaver-Brooks
  • Request Information    Back to top

    15. WATER TREATMENT SYSTEMS


    DEALKALIZER/DEMINERIALIZER
    Purpose: Improve boiler feed water quality, reduce boiler blowdown and reduce chemical usage. A chloride cycle dealkalizer is an ion exchange process that contains a strong base anion resin that is regenerated with salt brine and sodium hydroxide which exchanges alkalinity, sulfates, nitrates, carbon dioxide, and some silica for chloride ions. Dealkalizers are recommended when the bicarbonate alkalinity exceeds 100 ppm, makeup exceeds 1,000 gallons per day and the chloride count is below 120 PPM Demineralizer includes a strong acid cation (regenerated with sulfuric or hydrochloric acid) unit and strong basbase (sodium hydroxide) unit.
    Representing: Cleaver-Brooks

    Request Information    Back to top

    REVERSE OSMOSIS
    Purpose: Improve boiler feed water, reduce boiler blowdown and reduce chemical usage. Uses a semi-permeable membrane under pressure to reject dissolved salts and allow pure water to pass through. RO is recommended for Food Processing, Sterilization, or other applications requiring high purity water without the use of water treatment chemicals.
    Representing: Cleaver-Brooks

    16. WATER FILTERS
     

    WATER FILTERS
    Purpose: Remove excess impurities from system water supply. Carbon Filters, Multilayered Filters, Sand filters, and Iron Filters are available as required. Options include lined tanks, ASME code tanks, and automatic operation based upon time clock, pressure differential switch, or water meter.
    Representing: Cleaver-Brooks

    Request Information   Back to top

    17. THE BOILER BOOK

    THE BOILER BOOK
    Purpose: Provides a single source for consulting and specifying engineers for the purpose of selecting and specifying Cleaver-Brooks equipment.
    Features: The Boiler Book covers boilers for commercial, industrial, heating and processing applications. It is filled with schematics, illustrations and charts, plus comprehensive chapters on boiler selection, payback and ROI, steam and hot water systems, and accessory equipment. Request your copy today...
    Representing: Cleaver-Brooks


    Request Information   Back to top

    Water Filter and Reverse Osmosis System Water Softeners Chimney Automation  and Draft Controls Oxygen Trim System Multi System Boiler Controls Blowdown Separator Sample Cooler and Misc. Valves Heat Recovery System Chemical Feed Systems Deaerator Combustion Air System Dealkalizer Semi Instantaneous Water Heater Stacks and Breeching Economizer Boilers